What a result looks like

All samples contain fictitious data. They show how we evidence values, document clarifications and record the process up to submission: data preparation, expert review, sign-off by the manufacturer, submission in the manufacturer's EUDAMED account and the technical response from EUDAMED. The sample decision log is available in German, English and Turkish.

Example Fictitious data: no real device, no real customer, no real reviewer. The SRN DE-MF-000000000, the name Dr. Beispiel and the sample manufacturer are placeholders. None of the samples contains a genuine expert review or sign-off.

The device file

An excerpt from our sample decision log. Select a field in the device file to see the source document, the value transferred, the open question and the documented review. Below that you will find the expert review and the manufacturer's sign-off.

Device file, excerpt

Sample, fictitious data

Musterprodukt Mullkompresse 10x10 cm, steril

File
00000000-0000-4000-8000-000000000001
Manufacturer
Musterfirma Medizintechnik GmbH
SRN
DE-MF-000000000 placeholder

Example Example with fictitious data. The device, manufacturer, identifiers and the reviewer are not real. The sample contains no genuine expert review and no genuine sign-off.

Fields of the device file. Select a field to see its evidence.
FieldValueStatus
Basic UDI-DI 4099999MUSTER0001AB transferred
UDI-DI 04099999000017 resolved
Risk class Class Is, Rule 4, Annex VIII MDR transferred
EMDN code M0201020101 Cotton gauzes, folded, sterile transferred
Intended purpose from the instructions for use, revision 3 transferred
Sterilisation method STEAM resolved
Placed on the market sterile yes confirmed

Status per field: transferred (square), resolved after an open question (diamond), confirmed by the manufacturer (tick).

Evidence: Basic UDI-DI

  1. Source document

    The manufacturer's product list.

  2. Value transferred

    Value transferred unchanged from the product list.

  3. Open question

    No open question.

  4. Documented review

    Check point 4, mandatory fields complete: checked.

Evidence: UDI-DI

  1. Source document

    The manufacturer's product list. The UDI-DI field is empty.

  2. Value transferred

    No value transferred. A missing identifier is never guessed.

  3. Open question

    The UDI-DI is missing from the product list. Please add the identifier.

    Resolved on 3 September 2026: Your team enters the UDI-DI. The log records the change from empty to 04099999000017.

  4. Documented review

    Check point 4: all 28 mandatory fields are filled in.

Evidence: Risk class

  1. Source document

    The manufacturer's device details: non-invasive device, contact with injured skin, placed on the market sterile.

  2. Value transferred

    Class Is under Rule 4, Annex VIII MDR, transferred from the manufacturer's classification. The rule applied is recorded in the file.

  3. Open question

    No open question.

  4. Documented review

    Check point 2: risk class and application of the rule confirmed.

Evidence: EMDN code

  1. Source document

    The official EMDN nomenclature of the European Commission.

  2. Value transferred

    Terminal code M0201020101. Candidates reviewed from the nomenclature: M0201020101 and M020102.

  3. Open question

    No open question.

  4. Documented review

    Check point 1: EMDN code confirmed against the official nomenclature.

Evidence: Intended purpose

  1. Source document

    The manufacturer's instructions for use, revision 3.

  2. Value transferred

    Intended purpose transferred from the instructions for use. The wording is not reproduced in the sample.

  3. Open question

    No open question.

  4. Documented review

    Check point 3: intended purpose matches the instructions for use, rev. 3.

Evidence: Sterilisation method

  1. Source document

    Pre-filled value EO. The manufacturer's validation report states steam sterilisation.

  2. Value transferred

    Initially EO from the pre-filled value.

  3. Open question

    The pre-filled value and the validation report contradict each other. Which method applies?

    Resolved on 3 September 2026: Your team changes the value from EO to STEAM. Reason recorded in the log: source data preferred, the validation report states steam sterilisation.

  4. Documented review

    Check point 4: evidence of sterilisation supplied subsequently, mandatory fields complete.

Evidence: Placed on the market sterile

  1. Source document

    Pre-filled value from the device details.

  2. Value transferred

    Value pre-filled and put to your team for confirmation.

  3. Open question

    No open question.

    Your team confirms the pre-filled value on 3 September 2026.

  4. Documented review

    Check point 2: Class Is, meaning placed on the market sterile, confirmed.

Expert review and sign-off

Expert review by
Dr. Beispiel placeholder, not a real person
Date of review
4 September 2026
Review verdict
5 of 5 check points reviewed. Class and EMDN checked, no objections.
Sign-off by the manufacturer
7 September 2026, by the sample manufacturer a separate step, documented in the sample log
Submission
8 September 2026 in the sample manufacturer's EUDAMED account
EUDAMED response
SUCCESS on 9 September 2026. This is technical acceptance, not regulatory approval by an authority.

Values from the sample decision log, as of 26 October 2026, simplified for display.

Chain of events in the sample log

Every stage of the sample file is an event with a timestamp and the party involved. The order follows the process: data preparation, expert review, sign-off by the manufacturer, submission and the technical response from EUDAMED.

Events in the sample decision log, content shortened
No.TimeEventContentParty
11 September 2026, 10:00 File created Transferred from the manufacturer's product list, with the source of each value recorded. Medregia
21 September 2026, 10:00 Risk class transferred Class Is under Rule 4, Annex VIII MDR, from the manufacturer's classification. Medregia
31 September 2026, 10:00 EMDN code assigned M0201020101 checked against the official nomenclature, candidates M0201020101 and M020102. Medregia
42 September 2026, 11:30 Manufacturer's declaration Legal framework MDR. Reprocessed single-use devices under Article 17 MDR: no. Manufacturer
53 September 2026, 13:00 Open questions resolved UDI-DI from empty to 04099999000017. Sterilisation method from EO to STEAM; reason: the validation report states steam sterilisation. Manufacturer
63 September 2026, 13:05 Pre-filled values confirmed Placed on the market sterile, first EU country. A confirmation, not a sign-off. Manufacturer
73 September 2026, 13:10 Details confirmed 28 of 28 mandatory fields complete. A confirmation, not a sign-off. Manufacturer
84 September 2026, 09:15 Expert review Dr. Beispiel (placeholder), 5 of 5 check points reviewed, no objections. The review verdict is not a sign-off. Reviewer
97 September 2026, 16:00 Sign-off by the manufacturer The sample manufacturer (placeholder) signs off the reviewed record for submission. Manufacturer
108 September 2026, 08:00 Submitted to EUDAMED XML bulk upload DEVICE_POST_MUSTER.xml in the manufacturer's EUDAMED account DE-MF-000000000, one device. Medregia
119 September 2026, 08:30 Technical response from EUDAMED SUCCESS for 04099999000017. Technical acceptance, not regulatory approval by an authority. EUDAMED

The table can be scrolled sideways.

Confirmations by the manufacturer's team during preparation (events 6 and 7) are not a sign-off. The manufacturer gives its sign-off as a separate step after the expert review (event 9); the review verdict does not replace it.

The sample contains no verification key and no hash values because it does not come from a real file.

Review verdict in the sample

Review verdict of the sample expert review dated 4 September 2026
No.Check pointCheckedRemark
1EMDN code confirmed against the official nomenclature.yesM0201020101 is the terminal level for sterile, folded gauze swabs.
2Risk class and application of the rule under Annex VIII MDR confirmed.yesRule 4, Annex VIII MDR, contact with injured skin, Class Is.
3Intended purpose compared with the instructions for use.yesIntended purpose matches the instructions for use, rev. 3.
4Mandatory fields complete or gaps resolved.yesAll 28 mandatory fields filled in, evidence of sterilisation supplied subsequently.
5German and English device descriptions reviewed.yesGerman and English device descriptions correct in language and content.

Conclusion in the sample: file complete, no objections. The reviewer is a placeholder. The review verdict is not a sign-off; the manufacturer then gives its documented sign-off.

Sample files to download

The sample decision log is available in German, English and Turkish, each with the same events and values. The product name, manufacturer name, identifiers and technical codes are unchanged in all versions.

Sample files with format and document language
FileContentFormatLanguage
Sample decision log, English version
medregia-muster-entscheidungsprotokoll-en.pdf
The same steps, events and values as the German version. PDF English. Product name, manufacturer name, identifiers and codes unchanged.
Sample decision log, German version
medregia-muster-entscheidungsprotokoll.pdf
The sample file's process in five steps: data preparation, expert review, sign-off by the manufacturer, XML submission in the manufacturer's EUDAMED account, technical response from EUDAMED. No verification key. PDF German
Sample decision log, Turkish version
medregia-muster-entscheidungsprotokoll-tr.pdf
The same steps, events and values as the German version. PDF Turkish. Product name, manufacturer name, identifiers and codes unchanged.
Sample device list
medregia-muster-produktliste.csv
Five fictitious sample devices with the fields for each device. Semicolon-separated, UTF-8. CSV Column names in German with technical keys
Sample XML for bulk upload
medregia-muster-device-post.xml
DEVICE.POST package generated from the same device list; according to the file header, validated against the EUDAMED data exchange schema XSD 3.0.30. Not intended for upload. XML Technical data format, comments in German

The device list and the XML show five other fictitious sample devices with the same placeholder SRN, GS1 prefix 4099999 and certificate number MUSTER-CE-0000. They are not the submission of the sample file; the decision log shows its single device. No real device, no customer data.

Technical basis

Official EMDN nomenclature
We check against the European Commission's EMDN v3 with 8,487 codes across all levels, as of 7 September 2026. No catalogue of our own, no guessed codes.
Terminal code
For submission we use the lowest available level of the nomenclature, the terminal code. We do not accept higher-level categories.
Risk class from your classification
We transfer the risk class and the rule applied under Annex VIII MDR from your documents; we do not determine them ourselves.
Field catalogue
Based on Annex VI MDR. Every mandatory field is recorded and evidenced individually.
Schema validation before upload
The submission is generated as DEVICE.POST XML following the official EUDAMED data exchange schema and validated against it before upload. The sample XML states the schema version used in its file header.

Verify a decision log

A decision log from a Medregia file carries a verification key on its first page. Enter it here. We check whether the chain of events is unchanged and report the number of events and the time of the last one. The check does not display content, field values or names.

The check shows that the log is unchanged. It does not show that the details are correct in substance.

The samples on this page contain no verification key because they do not come from a real file, so they cannot be used to try out the check.

Printed on the first page of the log PDF for your file.

The check reads only the hash chain and shows no content. We do not store your entry in our database.

Clarify scope and way of working in four questions.

The project check gives you initial guidance straight away. Afterwards you can request a project proposal if you wish.

Clarify your project scope

Or write to us directly at kontakt@medregia.eu.